Tx1000 SeriesTelemetry Transmitter Installation Handbook Rev-01 Page 4 of 141
LAYOUT OF THE BBV Tx1000 KEYPAD
Connections
Having mounted the base unit on the wall or in a rack, continue as follows:
1. Connect the keypad to 9-pin d socket marked "Keypad 1".
2. Connect a BNC cable from output M1 to the keypad, and connect the other keypad connection to Monitor 1.
Terminate the cable at the monitor.
3. If the keypad is remotely sited from the base unit, connect the plug-mounted power supply to the keypad via the
2.1mm power connector.
4. Connect either a second spot monitor (no keypad and no text), or the second keypad to Output 2. Note that even if
both keypads are local to the main unit, the second keypad must be powered from the plug-mounted transformer.
5. Connect the BNC cables from the cameras/receivers to the upper BNC sockets in each row, marked "Camera
Inputs".
6. Connect any other equipment requiring the camera video signals to the lower BNC sockets marked "Video Out".
Note that the action of connecting to the video-out socket removes the 75Ω termination.
7. If the user relay terminals are being used, connect these to the LOW VOLTAGE equipment of your choice.
PIN 6
PIN 7
PIN 8
normally closed
common
normally open
8. Apply power via the IEC connector and switch on. The power LED should flash and the monitors should show
Camera 1 inputs